Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 56
Filter
1.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38571291

ABSTRACT

AIMS: Same-day discharge (SDD) after atrial fibrillation (AF) ablation is an effective means to spare healthcare resources. However, safety remains a concern, and besides structural adaptations, SDD requires more efficient logistics and coordination. Therefore, in this study, we implement a streamlined, nurse-coordinated SDD programme following a standardized protocol. METHODS AND RESULTS: As a dedicated SDD coordinator, a nurse specialized in ambulatory cardiac interventions was in charge of the full SDD protocol, including eligibility, patient flow, in-hospital logistics, patient education, and discharge as well as early post-discharge follow-up by smartphone-based virtual visits. Patients planned for AF ablation were considered eligible if they had a left ventricular ejection fraction (LVEF) ≥35%, with basic support at home and accessibility of the hospital within 60 min also forming a part of the eligibility criteria. A total of 420 consecutive patients were screened by the SDD coordinator, of whom 331 were eligible for SDD. The reasons for exclusion were living remotely (29, 6.9%), lack of support at home (19, 4.5%), or LVEF <35% (17, 4.0%). Of the eligible patients, 300 (91%) were successfully discharged the same day. There were no major post-SDD complications. Rates of unplanned medical attention (19, 6.3%) and 30-day readmission (5, 1.6%) were extremely low and driven by femoral access-site complications. These were significantly reduced upon the introduction of compulsory ultrasound-guided punctures after the initial 150 SDD patients (P = 0.0145). Standardized SDD coordination resulted in efficient workflows and reduced the total workload of the medical staff. CONCLUSION: Same-day discharge after AF ablation following a nurse-coordinated standardized protocol is safe and efficient. The concept of ambulatory cardiac intervention nurses functioning as dedicated coordinators may be key in the future transition of hospitals to SDD. Ultrasound-guided femoral puncture virtually eliminated relevant femoral access-site complications in our cohort and should therefore be a prerequisite for SDD.


Subject(s)
Atrial Fibrillation , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Patient Discharge , Stroke Volume , Aftercare , Ventricular Function, Left , Retrospective Studies , Treatment Outcome
2.
Cardiol Clin ; 41(3): 379-391, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37321688

ABSTRACT

Left bundle branch block (LBBB) is not just a simple electrocardiogram alteration. The intricacies of this general terminology go beyond simple conduction block. This review puts together current knowledge on the historical concept of LBBB, clinical significance, and recent insights into the pathophysiology of human LBBB. LBBB is an entity that affects patient diagnosis (primary conduction disease, secondary to underlying pathology or iatrogenic), treatment (cardiac resynchronization therapy or conduction system pacing for heart failure), and prognosis. Recruiting the left bundle branch with conduction system pacing depends on the complex interaction between anatomy, site of pathophysiology, and delivery tools.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Humans , Bundle-Branch Block/diagnosis , Bundle-Branch Block/therapy , Heart Conduction System , Electrocardiography , Prognosis , Treatment Outcome , Ventricular Function, Left
3.
Europace ; 25(6)2023 06 02.
Article in English | MEDLINE | ID: mdl-37294671

ABSTRACT

AIMS: To define a stepwise application of left bundle branch pacing (LBBP) criteria that will simplify implantation and guarantee electrical resynchronization. Left bundle branch pacing has emerged as an alternative to biventricular pacing. However, a systematic stepwise criterion to ensure electrical resynchronization is lacking. METHODS AND RESULTS: A cohort of 24 patients from the LEVEL-AT trial (NCT04054895) who received LBBP and had electrocardiographic imaging (ECGI) at 45 days post-implant were included. The usefulness of ECG- and electrogram-based criteria to predict accurate electrical resynchronization with LBBP were analyzed. A two-step approach was developed. The gold standard used to confirm resynchronization was the change in ventricular activation pattern and shortening in left ventricular activation time, assessed by ECGI. Twenty-two (91.6%) patients showed electrical resynchronization on ECGI. All patients fulfilled pre-screwing requisites: lead in septal position in left-oblique projection and W paced morphology in V1. In the first step, presence of either right bundle branch conduction delay pattern (qR or rSR in V1) or left bundle branch capture Plus (QRS ≤120 ms) resulted in 95% sensitivity and 100% specificity to predict LBBP resynchronization, with an accuracy of 95.8%. In the second step, the presence of selective capture (100% specificity, only 41% sensitivity) or a spike-R <80 ms in non-selective capture (100% specificity, sensitivity 46%) ensured 100% accuracy to predict resynchronization with LBBP. CONCLUSION: Stepwise application of ECG and electrogram criteria may provide an accurate assessment of electrical resynchronization with LBBP (Graphical abstract).


Subject(s)
Bundle of His , Cardiac Resynchronization Therapy , Humans , Bundle-Branch Block/diagnosis , Bundle-Branch Block/therapy , Cardiac Pacing, Artificial/methods , Cardiac Resynchronization Therapy/methods , Electrocardiography/methods , Heart Conduction System , Treatment Outcome
4.
Rev Esp Cardiol (Engl Ed) ; 76(12): 970-979, 2023 Dec.
Article in English, Spanish | MEDLINE | ID: mdl-37028797

ABSTRACT

INTRODUCTION AND OBJECTIVES: The role of [18F]FDG-PET/CT in cardiac implantable electronic device (CIED) infections requires better evaluation, especially in the diagnosis of systemic infections. We aimed to determine the following: a) the diagnostic accuracy of [18F]FDG-PET/CT in each CIED topographical region, b) the added value of [18F]FDG-PET/CT over transesophageal echocardiography (TEE) in diagnosing systemic infections, c) spleen and bone marrow uptake in differentiating isolated local infections from systemic infections, and d) the potential application of [18F]FDG-PET/CT in follow-up. METHODS: Retrospective single-center study including 54 cases and 54 controls from 2014 to 2021. The Primary endpoint was the diagnostic yield of [18F]FDG-PET/CT in each topographical CIED region. Secondary analyses described the performance of [18F]FDG-PET/CT compared with that of TEE in systemic infections, bone marrow and spleen uptake in systemic and isolated local infections, and the potential application of [18F]FDG-PET/CT in guiding cessation of chronic antibiotic suppression when completed device removal is not performed. RESULTS: We analyzed 13 (24%) isolated local infections and 41 (76%) systemic infections. Overall, the specificity of [18F]FDG-PET/CT was 100% and sensitivity 85% (79% pocket, 57% subcutaneous lead, 22% endovascular lead, 10% intracardiac lead). When combined with TEE, [18F]FDG-PET/CT increased definite diagnosis o fsystemic infections from 34% to 56% (P=.04). Systemic infections with bacteremia showed higher spleen (P=.05) and bone marrow metabolism (P=.04) than local infections. Thirteen patients without complete device removal underwent a follow-up [18F]FDG-PET/CT, with no relapses after discontinuation of chronic antibiotic suppression in 6 cases with negative follow-up [18F]FDG-PET/CT. CONCLUSIONS: The sensitivity of [18F]FDG-PET/CT for evaluating CIED infections was high in local infections but much lower in systemic infections. However, accuracy increased when [18F]FDG-PET/CT was combined with TEE in endovascular lead bacteremic infection. Spleen and bone marrow hypermetabolism could differentiate bacteremic systemic infection from local infection. Although further prospective studies are needed, follow-up [18F]FDG-PET/CT could play a potential role in the management of chronic antibiotic suppression therapy when complete device removal is unachievable.


Subject(s)
Defibrillators, Implantable , Heart Diseases , Pacemaker, Artificial , Prosthesis-Related Infections , Sepsis , Humans , Positron Emission Tomography Computed Tomography , Fluorodeoxyglucose F18 , Defibrillators, Implantable/adverse effects , Pacemaker, Artificial/adverse effects , Radiopharmaceuticals/pharmacology , Retrospective Studies , Heart Diseases/therapy , Anti-Bacterial Agents , Prosthesis-Related Infections/diagnostic imaging , Prosthesis-Related Infections/therapy
6.
JACC Clin Electrophysiol ; 8(11): 1431-1445, 2022 11.
Article in English | MEDLINE | ID: mdl-36424012

ABSTRACT

BACKGROUND: Conduction system pacing (CSP) has emerged as an alternative to biventricular pacing (BiVP). Randomized studies comparing both therapies are scarce and do not include left bundle branch pacing. OBJECTIVES: This study aims to compare ventricular resynchronization achieved by CSP vs BiVP in patients with cardiac resynchronization therapy indication. METHODS: LEVEL-AT (Left Ventricular Activation Time Shortening with Conduction System Pacing vs Biventricular Resynchronization Therapy) was a randomized, parallel, controlled, noninferiority trial. Seventy patients with cardiac resynchronization therapy indication were randomized 1:1 to BiVP or CSP, and followed up for 6 months. Crossover was allowed when primary allocation procedure failed. Primary endpoint was the change in left ventricular activation time, measured using electrocardiographic imaging. Secondary endpoints were left ventricular reverse remodeling and the combined endpoint of heart failure hospitalization or death at 6-month follow-up. RESULTS: Thirty-five patients were allocated to each group. Eight (23%) patients crossed over from CSP to BiVP; 2 patients (6%) crossed over from BiVP to CSP. Electrocardiographic imaging could not be performed in 2 patients in each group. A similar decrease in left ventricular activation time was achieved by CSP and BiVP (-28 ± 26 ms vs -21 ± 20 ms, respectively; mean difference -6.8 ms; 95% CI: -18.3 ms to 4.6 ms; P < 0.001 for noninferiority). Both groups showed a similar change in left ventricular end-systolic volume (-37 ± 59 mL CSP vs -30 ± 41 mL BiVP; mean difference: -8 mL; 95% CI: -33 mL to 17 mL; P = 0.04 for noninferiority) and similar rates of mortality or heart failure hospitalizations (2.9% vs 11.4%, respectively) (P = 0.002 for noninferiority). CONCLUSIONS: Similar degrees of cardiac resynchronization, ventricular reverse remodeling, and clinical outcomes were attained by CSP as compared to BiVP. CSP could be a feasible alternative to BiVP. (LEVEL-AT [Left Ventricular Activation Time Shortening With Conduction System Pacing vs Biventricular Resynchronization Therapy]; NCT04054895).


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Humans , Cardiac Resynchronization Therapy/methods , Heart Conduction System , Bundle-Branch Block , Cardiac Conduction System Disease/therapy , Ventricular Remodeling
7.
Open Forum Infect Dis ; 9(11): ofac547, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36381626

ABSTRACT

Background: Studies investigating cardiac implantable electronic device infective endocarditis (CIED-IE) epidemiological changes and prognosis over long periods of time are lacking. Methods: Retrospective single cardiovascular surgery center cohort study of definite CIED-IE episodes between 1981-2020. A comparative analysis of two periods (1981-2000 vs 2001-2020) was conducted to analyze changes in epidemiology and outcome over time. Results: One-hundred and thirty-eight CIED-IE episodes were diagnosed: 25 (18%) first period and 113 (82%) second. CIED-IE was 4.5 times more frequent in the second period, especially in implantable cardiac defibrillators. Age (63 [53-70] vs 71 [63-76] years, P < .01), comorbidities (CCI 3.0 [2-4] vs 4.5 [3-6], P > .01), nosocomial infections (4% vs 15.9%, P = .02) and transfers from other centers (8% vs 41.6%, P < .01) were significantly more frequent in the second period, as were methicillin-resistant coagulase-negative staphylococcal (MR-CoNS) (0% vs 13.3%, P < .01) and Enterococcus spp. (0% vs 5.3%, P = .01) infections, pulmonary embolism (0% vs 10.6%, P < .01) and heart failure (12% vs 28.3%, p < .01). Second period surgery rates were lower (96% vs 87.6%, P = .09), and there were no differences in in-hospital (20% vs 11.5%, P = .11) and one-year mortalities (24% vs 15%, P = .33), or relapses (8% vs 5.3%, P = 0.65). Multivariate analysis showed Charlson index (hazard ratios [95% confidence intervals]; 1.5 [1.16-1.94]) and septic shock (23.09 [4.57-116.67]) were associated with a worse prognosis, whereas device removal (0.11 [.02-.57]), transfers (0.13 [.02-0.95]), and second-period diagnosis (0.13 [.02-.71]) were associated with better one-year outcomes. Conclusions: CIED-IE episodes increased more than four-fold during last 40 years. Despite CIED-IE involved an older population with more comorbidities, antibiotic-resistant MR-CoNS, and complex devices, one-year survival improved.

8.
Pacing Clin Electrophysiol ; 45(9): 1115-1123, 2022 09.
Article in English | MEDLINE | ID: mdl-35583311

ABSTRACT

BACKGROUND: It is unknown whether His-Purkinje conduction system pacing (HPCSP), as either His bundle or left bundle branch pacing, could be an alternative to cardiac resynchronization therapy (BiVCRT) for patients with left ventricular dysfunction needing ventricular pacing due to atrioventricular block. The aim of the study is to compare the echocardiographic response and clinical improvement between HPCSP and BiVCRT. METHODS: Consecutive patients who successfully received HPCSP were compared with a historical cohort of BiVCRT patients. Patients were 1:1 matched by age, LVEF, atrial fibrillation, renal function and cardiomyopathy type. Responders were defined as patients who survived, did not require heart transplantation and increased LVEF ≥5 points at 6-month follow-up. RESULTS: HPCSP was successfully achieved in 92.5% (25/27) of patients. During follow-up, 8% (2/25) of HPCSP patients died and 4% (1/25) received a heart transplant, whereas 4% (1/25) of those in the BiVCRT cohort died. LVEF improvement was 10% ± 8% HPCSP versus 7% ± 5% BiVCRT (p = .24), and the percentage of responders was 76% (19/25) HPCSP versus 64% (16/25) BiVCRT (p = .33). Among survivors, the percentage of patients who improved from baseline II-IV mitral regurgitation (MR) to 0-I MR was 9/11 (82%) versus 2/8 (25%) (p = .02). Compared to those with BiVCRT, patients with HPCSP achieved better NYHA improvement: 1 point versus 0.5 (OR 0.34; p = .02). CONCLUSION: HPCSP in patients with LVEF ≤45% and atrioventricular block improved the LVEF and induced a response similar to that of BiVCRT. HPCSP significantly improved MR and NYHA functional class. HPCSP may be an alternative to BiVCRT in these patients. (Figure 1. Central Illustration). [Figure: see text].


Subject(s)
Atrioventricular Block , Cardiac Resynchronization Therapy , Heart Failure , Ventricular Dysfunction , Bundle of His , Cardiac Conduction System Disease , Cardiac Pacing, Artificial/adverse effects , Cardiac Resynchronization Therapy/adverse effects , Heart Failure/therapy , Humans , Stroke Volume , Treatment Outcome , Ventricular Dysfunction/etiology , Ventricular Dysfunction/therapy , Ventricular Function, Left
9.
Pacing Clin Electrophysiol ; 45(3): 374-383, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35015308

ABSTRACT

BACKGROUND: His-Purkinje conduction system pacing (HPCSP) has been proposed as an alternative to Cardiac Resynchronization Therapy (CRT); however, predictors of echocardiographic response have not been described in this population. Septal flash (SF), a fast contraction and relaxation of the septum, is a marker of intraventricular dyssynchrony. METHODS: The study aimed to analyze whether HPCSP corrects SF in patients with CRT indication, and if correction of SF predicts echocardiographic response. This retrospective analysis of prospectively collected data included 30 patients. Left ventricular ejection fraction (LVEF) was measured with echocardiography at baseline and at 6-month follow-up. Echocardiographic response was defined as increase in five points in LVEF. RESULTS: HPCSP shortened QRS duration by 48 ± 21 ms and SF was significantly decreased (baseline 3.6 ± 2.2 mm vs. HPCSP 1.5 ± 1.5 mm p < .0001). At 6-month follow-up, mean LVEF improvement was 8.6% ± 8.7% and 64% of patients were responders. There was a significant correlation between SF correction and increased LVEF (r = .61, p = .004). A correction of ≥1.5 mm (baseline SF - paced SF) had a sensitivity of 81% and 80% specificity to predict echocardiographic response (area under the curve 0.856, p = .019). CONCLUSION: HPCSP improves intraventricular dyssynchrony and results in 64% echocardiographic responders at 6-month follow-up. Dyssynchrony improvement with SF correction may predict echocardiographic response at 6-month follow-up.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Ventricular Dysfunction, Left , Cardiac Pacing, Artificial , Cardiac Resynchronization Therapy/methods , Echocardiography , Heart Failure/therapy , Heart Ventricles , Humans , Retrospective Studies , Stroke Volume/physiology , Treatment Outcome , Ventricular Dysfunction, Left/prevention & control , Ventricular Function, Left
10.
Card Electrophysiol Clin ; 13(4): 671-684, 2021 12.
Article in English | MEDLINE | ID: mdl-34689894

ABSTRACT

Left bundle branch block (LBBB) is not just a simple electrocardiogram alteration. The intricacies of this general terminology go beyond simple conduction block. This review puts together current knowledge on the historical concept of LBBB, clinical significance, and recent insights into the pathophysiology of human LBBB. LBBB is an entity that affects patient diagnosis (primary conduction disease, secondary to underlying pathology or iatrogenic), treatment (cardiac resynchronization therapy or conduction system pacing for heart failure), and prognosis. Recruiting the left bundle branch with conduction system pacing depends on the complex interaction between anatomy, site of pathophysiology, and delivery tools.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Bundle-Branch Block/therapy , Electrocardiography , Heart Conduction System , Heart Failure/therapy , Humans
12.
Antimicrob Agents Chemother ; 65(10): e0252220, 2021 09 17.
Article in English | MEDLINE | ID: mdl-34252304

ABSTRACT

Abiotrophia and Granulicatella species are fastidious organisms, representing the causative agents of ∼1% to 3% of cases of infective endocarditis (IE). Little is known about the optimal antibiotic treatment for these species, and daptomycin has been suggested as a therapeutic option. We describe the antimicrobial profiles of Abiotrophia and Granulicatella IE isolates, investigate high-level daptomycin resistance (HLDR) development, and evaluate daptomycin activity in combination therapy. In vitro studies with 16 IE strains (6 Abiotrophia defectiva strains, 9 Granulicatella adiacens strains, and 1 G. elegans strain) were performed using microdilution to determine MICs and time-kill methodology to evaluate combination therapy. Daptomycin nonsusceptibility (DNS) (MIC ≥ 2 mg/liter) and HLDR (MIC ≥ 256 mg/liter) were based on existing Clinical and Laboratory Standards Institute (CLSI) breakpoints for viridans group streptococci. All isolates were susceptible to vancomycin: G. adiacens was more susceptible to penicillin and ampicillin than A. defectiva (22% versus 0% and 67% versus 33%) but less susceptible to ceftriaxone and daptomycin (56% versus 83% and 11% versus 50%). HLDR developed in both A. defectiva (33%) and G. adiacens (78%) after 24 h of exposure to daptomycin. Combination therapy did not prevent the development of daptomycin resistance with ampicillin (2/3 strains), gentamicin (2/3 strains), ceftriaxone (2/3 strains), or ceftaroline (2/3 strains). Once developed, HLDR was stable for a prolonged time (>3 weeks) in G. adiacens, whereas in A. defectiva, HLDR reversed to the baseline MIC at day 10. This study is the first to demonstrate rapid HLDR development in Abiotrophia and Granulicatella species in vitro. Resistance was stable, and most combination therapies did not prevent it.


Subject(s)
Abiotrophia , Daptomycin , Endocarditis, Bacterial , Anti-Bacterial Agents/pharmacology , Carnobacteriaceae , Daptomycin/pharmacology , Endocarditis, Bacterial/drug therapy , Humans
13.
J Antimicrob Chemother ; 76(6): 1539-1546, 2021 05 12.
Article in English | MEDLINE | ID: mdl-33837406

ABSTRACT

OBJECTIVES: To investigate if the addition of cloxacillin to vancomycin enhances the activity of both monotherapies for treating MSSA and MRSA experimental endocarditis (EE) in rabbits. METHODS: Vancomycin plus cloxacillin was compared with the respective monotherapies and daptomycin. In vitro time-kill studies were performed using standard (105 cfu) and high (108 cfu) inocula of five MRSA, one glycopeptide-intermediate (GISA) and five MSSA strains. One MSSA (MSSA-678) and one MRSA (MRSA-277) strain were selected to be used in the in vivo model. A human-like pharmacokinetics model was applied and the equivalents of cloxacillin 2 g/4 h IV and daptomycin 6 mg/kg/day IV were administered. To optimize vancomycin activity, dosage was adjusted to achieve an AUC/MIC ≥400. RESULTS: Daptomycin sterilized significantly more vegetations than cloxacillin (13/13, 100% versus 9/15, 60%; P = 0.02) and showed a trend of better activity than vancomycin (10/14, 71%; P = 0.09) and vancomycin plus cloxacillin (10/14, 71%; P = 0.09) against MSSA-678. Addition of cloxacillin to vancomycin (13/15, 87%) was significantly more effective than vancomycin (8/16, 50%; P = 0.05) and showed similar activity to daptomycin (13/18, 72%; P = 0.6) against MRSA-277. In all treatment arms, the bacterial isolates recovered from vegetations were re-tested and showed the same daptomycin susceptibility as the original strains. CONCLUSIONS: Vancomycin plus cloxacillin proved synergistic and bactericidal activity against MRSA. Daptomycin was the most efficacious option against MSSA and similar to vancomycin plus cloxacillin against MRSA. In settings with high MRSA prevalence, vancomycin plus cloxacillin might be a good alternative for empirical therapy of S. aureus IE.


Subject(s)
Daptomycin , Endocarditis, Bacterial , Endocarditis , Methicillin-Resistant Staphylococcus aureus , Animals , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/therapeutic use , Cloxacillin , Endocarditis/drug therapy , Endocarditis, Bacterial/drug therapy , Methicillin/pharmacology , Methicillin Resistance , Microbial Sensitivity Tests , Rabbits , Staphylococcus aureus , Vancomycin
14.
Infect Dis Ther ; 10(2): 1073-1080, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33721294

ABSTRACT

Mycobacterium wolinskyi is a rapid-growth non-tuberculous mycobacterium. Twenty-one cases of M. wolinskyi infection have been described so far, more than half as cardiovascular or postoperative cardiothoracic infections. We report the case of a patient with a cardiovascular implantable electronic device infected by M. wolinskyi, successfully treated with device removal and antimicrobials.

15.
Europace ; 22(9): 1391-1400, 2020 09 01.
Article in English | MEDLINE | ID: mdl-32898254

ABSTRACT

AIMS: Sudden cardiac death (SCD) risk estimation in patients referred for cardiac resynchronization therapy (CRT) remains a challenge. By CRT-mediated improvement of left ventricular ejection fraction (LVEF), many patients loose indication for primary prevention implantable cardioverter-defibrillator (ICD). Increasing evidence shows the importance of myocardial scar for risk prediction. The aim of this study was to investigate the prognostic impact of myocardial scar depending on the echocardiographic response in patients undergoing CRT. METHODS AND RESULTS: Patients with indication for CRT were prospectively enrolled. Decision about ICD or pacemaker implantation was based on clinical criteria. All patients underwent delayed-enhancement cardiac magnetic resonance imaging. Median follow-up duration was 45 (24-75) months. Primary outcome was a composite of sustained ventricular arrhythmia, appropriate ICD therapy, or SCD. A total of 218 patients with LVEF 25.5 ± 6.6% were analysed [158 (73%) male, 64.9 ± 10.7 years]. Myocardial scar was observed in 73 patients with ischaemic cardiomyopathy (ICM) (95% of ICM patients); in 62 with non-ischaemic cardiomyopathy (45% of these patients); and in all but 1 of 36 (17%) patients who reached the primary outcome. Myocardial scar was the only significant predictor of primary outcome [odds ratio 27.7 (3.8-202.7)], independent of echocardiographic CRT response. A total of 55 (25%) patients died from any cause or received heart transplant. For overall survival, only a combination of the absence of myocardial scar with CRT response was associated with favourable outcome. CONCLUSION: Malignant arrhythmic events and SCD depend on the presence of myocardial scar but not on CRT response. All-cause mortality improved only with the combined absence of myocardial scar and CRT response.


Subject(s)
Cardiac Resynchronization Therapy , Defibrillators, Implantable , Heart Failure , Arrhythmias, Cardiac , Cicatrix/diagnostic imaging , Cicatrix/pathology , Death, Sudden, Cardiac/prevention & control , Heart Failure/therapy , Humans , Male , Risk Factors , Stroke Volume , Treatment Outcome , Ventricular Function, Left
16.
J Antimicrob Chemother ; 75(12): 3586-3592, 2020 12 01.
Article in English | MEDLINE | ID: mdl-32853336

ABSTRACT

BACKGROUND: In vitro and in vivo activity of daptomycin alone or plus either cloxacillin or fosfomycin compared with cloxacillin alone and cloxacillin plus gentamicin were evaluated in a rabbit model of MSSA experimental endocarditis (EE). METHODS: Five MSSA strains were used in the in vitro time-kill studies at standard (105-106 cfu/mL) and high (108 cfu/mL) inocula. In the in vivo EE model, the following antibiotic combinations were evaluated: cloxacillin (2 g/4 h) alone or combined with gentamicin (1 mg/kg/8 h) or daptomycin (6 mg/kg once daily); and daptomycin (6 mg/kg/day) alone or combined with fosfomycin (2 g/6 h). RESULTS: At standard and high inocula, daptomycin plus fosfomycin or cloxacillin were bactericidal against 4/5 and 5/5 strains, respectively, while cloxacillin plus gentamicin was bactericidal against 3/5 strains at standard inocula but against none at high inocula. Fosfomycin, cloxacillin, gentamicin and daptomycin MIC/MBCs of the MSSA-678 strain used in the EE model were: 8/64, 0.25/0.5, 0.25/0.5 and 1/8 mg/L, respectively. Adding gentamicin to cloxacillin significantly reduced bacterial density in vegetations compared with cloxacillin monotherapy (P = 0.026). Adding fosfomycin or cloxacillin to daptomycin [10/11 (93%) and 8/11 (73%), respectively] significantly improved the efficacy of daptomycin in sterilizing vegetations [0/11 (0%), P < 0.001 for both combinations] and showed better activity than cloxacillin alone [0/10 (0%), P < 0.001 for both combinations] and cloxacillin plus gentamicin [3/10 (30%), P = 0.086 for cloxacillin plus daptomycin and P = 0.008 for fosfomycin plus daptomycin]. No recovered isolates showed increased daptomycin MIC. CONCLUSIONS: The addition of cloxacillin or fosfomycin to daptomycin is synergistic and rapidly bactericidal, showing better activity than cloxacillin plus gentamicin for treating MSSA EE, supporting their clinical use.


Subject(s)
Daptomycin , Endocarditis, Bacterial , Endocarditis , Fosfomycin , Animals , Anti-Bacterial Agents/therapeutic use , Cloxacillin , Endocarditis/drug therapy , Endocarditis, Bacterial/drug therapy , Gentamicins , Microbial Sensitivity Tests , Rabbits
17.
Europace ; 22(4): 598-606, 2020 04 01.
Article in English | MEDLINE | ID: mdl-32101605

ABSTRACT

AIMS: Ventricular tachycardia (VT) substrate-based ablation has become a standard procedure. Electroanatomical mapping (EAM) detects scar tissue heterogeneity and define conduction channels (CCs) that are the ablation target. Late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) is able to depict CCs and increase ablation success. Most patients undergoing VT ablation have an implantable cardioverter-defibrillator (ICD) that can cause image artefacts in LGE-CMR. Recently wideband (WB) LGE-CMR sequence has demonstrated to decrease these artefacts. The aim of this study is to analyse accuracy of WB-LGE-CMR in identifying the CC entrances. METHODS AND RESULTS: Thirteen consecutive ICD-patients who underwent VT ablation after WB-LGE-CMR were included. Number and location of CC entrances in three-dimensional EAM and in WB-LGE-CMR reconstruction were compared. Concordance was compared with a historical cohort matched by cardiomyopathy, scar location, and age (26 patients) with LGE-CMR prior to ICD and VT ablation. In WB-CMR group, 101 and 93 CC entrances were identified in EAM and WB-LGE-CMR, respectively. In historical cohort, 179 CC entrances were identified in both EAM and LGE-CMR. The EAM/CMR concordance was 85.1% and 92.2% in the WB and historical group, respectively (P = 0.66). There were no differences in false-positive rate (CC entrances detected in CMR and absent in EAM: 7.5% vs 7.8% in WB vs. conventional CMR, P = 0.92) nor in false-negative rate (CC entrances present in EAM not detected in CMR: 14.9% vs.7.8% in WB vs. conventional CMR, P = 0.23). Epicardial CCs was predictor of poor CMR/EAM concordance (OR 2.15, P = 0.031). CONCLUSION: Use of WB-LGE-CMR sequence in ICD-patients allows adequate VT substrate characterization to guide VT ablation with similar accuracy than conventional LGE-CMR in patients without an ICD.


Subject(s)
Defibrillators, Implantable , Tachycardia, Ventricular , Cicatrix/diagnostic imaging , Cicatrix/pathology , Contrast Media , Gadolinium , Humans , Magnetic Resonance Imaging , Magnetic Resonance Spectroscopy , Myocardium/pathology , Tachycardia, Ventricular/diagnostic imaging , Tachycardia, Ventricular/pathology , Tachycardia, Ventricular/surgery
18.
J Cardiovasc Electrophysiol ; 31(4): 868-874, 2020 04.
Article in English | MEDLINE | ID: mdl-31967367

ABSTRACT

BACKGROUND: Micra transcatheter pacemaker system (TPS) usually achieves low implant pacing threshold (IPT). However, IPT may increase in some patients during follow-up. AIM: To apply implant parameters in predicting long-term occurrence of very high pacing threshold (VHPT) in patients with Micra-TPS. METHODS: A cohort of 110 consecutive patients implanted with a Micra-TPS from 2014 to 2018 was evaluated at discharge and at 1, 12, 24, 36, and 48 months follow-up. VHPT was defined as greater than 2 V/0.24 ms. VHPT predictors were identified. RESULTS: Micra-TPS was implanted successfully in 108 patients (98.2%). During a mean follow-up of 24 ± 16 months, 18 patients (16.7%) died of causes nonpacemaker-related, and 4 (3.8%) developed VHPT. Patients with VHPT had higher IPT and lower implant impedance than patients with non-VHPT: 1 ± 0.31 vs 0.55 ± 0.29 V/0.24 ms (P = .003) and 580 ± 59 vs 837 ± 232 Ω (P = .03), respectively. IPT and impedance had excellent discriminative power to predict VHPT (area under the curve: 0.85 ± 0.07 and 0.91 ± 0.05, respectively). Negative predictive value (NPV) of IPT ≤ 0.5 V/0.24 ms was 100%; positive predictive value (PPV) was 8% throughout follow-up. Implant impedance ≤ 600 Ω had NPV of 99% throughout follow-up, whereas PPV varied: 16%, 21%, 16%, and 28% at 1, 12, 24, and 36 months, respectively. Sequential combination of IPT greater than 0.5 V/0.24 ms and impedance ≤ 600 Ω improved PPV to 25%, 35%, 27%, and 44%, respectively, whereas NPV remained 99% throughout follow-up. CONCLUSION: Despite favorable long-term electrical performance of Micra-TPS, a small percent of patients developed VHPT during follow-up. A sequential combination of IPT and impedance could allow the implanter to identify patients who will develop VHPT during long-term follow-up.


Subject(s)
Arrhythmias, Cardiac/therapy , Cardiac Pacing, Artificial , Pacemaker, Artificial , Adult , Aged , Aged, 80 and over , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/mortality , Arrhythmias, Cardiac/physiopathology , Cardiac Pacing, Artificial/adverse effects , Cardiac Pacing, Artificial/mortality , Electric Impedance , Electric Power Supplies , Equipment Design , Female , Humans , Male , Middle Aged , Time Factors , Treatment Outcome , Young Adult
19.
JACC Case Rep ; 2(14): 2225-2229, 2020 Nov 18.
Article in English | MEDLINE | ID: mdl-34317145

ABSTRACT

His bundle pacing was developed while seeking a physiological alternative to biventricular cardiac resynchronization therapy. However, His bundle pacing may not be adequate in all patients. In this scenario, left bundle branch pacing has arisen as a new cardiac resynchronization therapy modality to correct left bundle branch block and restore ventricular synchrony. (Level of Difficulty: Intermediate.).

SELECTION OF CITATIONS
SEARCH DETAIL
...